Sign or outline lighting system equipment shall be at least________ ft\mathrm{ft} above areas accessible to vehicles unless protected from physical damage.

Correct Answer

verifed

verified

Appliance receptacle outlets installed in a dwelling unit for specific appliances, such as laundry equipment, shall be installed within_________ ft\mathrm{ft} of the intend-ed location of the appliance.

Correct Answer

verifed

verified

A receptacle outlet shall be installed at each kitchen wall countertop space that is_________ in. or wider.

Correct Answer

verifed

verified

A(n)\mathrm{A}(\mathrm{n}) _________is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when an arc fault is detected.

Correct Answer

verifed

verified

Arc-Fault ...

View Answer

Outdoor mobile home disconnecting means shall be installed so the center of the grip of the operating handle, when in the highest position, is not more than ________(\mathrm{ft}________in. above the finished grade or working platform.

Correct Answer

verifed

verified

\(A(n) _________ is defined as the connection between the grounded circuit conductor and the supply-side bonding jumper, or the equipment grounding conductor, or both, at a separately derived system.

Correct Answer

verifed

verified

System bon...

View Answer

The service equipment shall be located in sight from and not more than_________ ft\mathrm{ft} from the exterior wall of the mobile home it serves.

Correct Answer

verifed

verified

Interior metal water piping that is electrically continuous with a metal underground water pipe electrode and is located not more than_________ ft\mathrm{ft} from the point of entrance to the building shall be permitted to extend the connection to the grounding electrode(s).

Correct Answer

verifed

verified

Conductors shall be considered outside of a building or other structure where installed under not less than_________ in. of concrete beneath a building or other structure.

Correct Answer

verifed

verified

When calculating track lighting loads for a commercial service, an additional load of ______volt-amperes shall be included for every ______ ft\mathrm{ft} of lighting track or fraction thereof.

Correct Answer

verifed

verified

Service conductors installed as open conductors shall have a clearance of not less than_________ ft\mathrm{ft} from windows that are designed to be opened.

Correct Answer

verifed

verified

The ampacity of the supply conductors for a resistance welder that may be operated at different times at different values of primary current or duty cycle shall not be less than _________of the rated primary current for seam and automatically fed welders.

Correct Answer

verifed

verified

A metal pole, supporting a luminaire, does not require a handhole if the pole is ______ ft\mathrm{ft} or less in height above grade where the supply wiring method continues without splice or pull point, and where the interior of the pole and any splices are accessible by removing the luminaire.

Correct Answer

verifed

verified

A door sill or curb that is of an approved height that will confine the oil from the largest transformer within the vault shall be provided, and in no case shall the height be less than ________in.

Correct Answer

verifed

verified

A clearly labeled emergency shutoff or control switch for the purpose of stopping the motor(s) that provide power to the recirculation system and jet system shall be installed at a point readily accessible to the users and at least _________ ft away adjacent to, and within sight of the spa or hot tub.

Correct Answer

verifed

verified

In other than dwelling units, in addition to other arcflash hazard warning requirements in this section, a permanent label shall be field or factory applied to service equipment rated _________amps or more.

Correct Answer

verifed

verified

A grounded circuit conductor shall be permitted to ground non-current-carrying metal parts of equipment on the __________ side of the ac service-disconnecting means

Correct Answer

verifed

verified

Aircraft energizers shall be designed and mounted such that all electric equipment and fixed wiring will be at least________ in. above floor level.

Correct Answer

verifed

verified

Shore power for boats shall be provided by single receptacles rated not less than________ amperes.

Correct Answer

verifed

verified

A compartment or chamber to which one or more air ducts are connected and that forms part of the air distribution system is a(n)a(n) _________.

Correct Answer

verifed

verified