Filters
Question type

Study Flashcards

To determine the allowable combination of exposures factors, thus preventing x-ray tube damage,


A) a tube rating chart is referenced after exposure to check correctness.
B) the automatic exposure circuit is activated.
C) an x-ray tube rating chart is checked prior to exposure.
D) an anode cooling chart is referenced prior to exposure.

Correct Answer

verifed

verified

How many heat units are generated by three (3) exposures of 100 kVp, 400 mA, and 0.01 second using a high frequency generator?

Correct Answer

verifed

verified

Which of the following would affect the production of a thermionic cloud?


A) filament diameter
B) filament length
C) filament temperature
D) all of the above

Correct Answer

verifed

verified

Why is a vacuum created in the x-ray tube?

Correct Answer

verifed

verified

The removal of air permits ele...

View Answer

The rotor is located ____ the stator and ____ the envelope.


A) inside; inside
B) inside; outside
C) outside; outside
D) outside; inside

Correct Answer

verifed

verified

When radiographing a wedge-shaped anatomical structure such as the femur, the thicker portion of the anatomy should be positioned


A) under the cathode end of the tube.
B) in the exact center of the beam. as it is most intense in the center.
C) off center laterally to negate the heel effect.
D) under the anode side of the tube.

Correct Answer

verifed

verified

The exact point on the anode where the x-ray beam emanates is the


A) focusing cup.
B) focal spot.
C) stator.
D) rotor.

Correct Answer

verifed

verified

B

As the angle of the anode increases and the incident electron beam size remains the same, the effective focal spot size


A) increases.
B) decreases.
C) remains the same.
D) cannot be determined.

Correct Answer

verifed

verified

The only portion of the anode assembly placed outside the vacuum of the envelope is the


A) stator.
B) rotor.
C) rotating disc.
D) molybdenum neck.

Correct Answer

verifed

verified

What type of radiation is composed of photons not produced at the actual focal spot?


A) off-focus
B) extrafocal
C) both a and b
D) primary

Correct Answer

verifed

verified

List two other names for the anode target.

Correct Answer

verifed

verified

target, focus, focal...

View Answer

X-ray photon production occurs at the


A) anode.
B) cathode.
C) filament.
D) stator.

Correct Answer

verifed

verified

The focusing cup has a/an ____ charge.


A) neutral
B) atomic
C) positive
D) negative

Correct Answer

verifed

verified

D

The problem of off-focus radiation


A) is particularly important with digital detectors.
B) distorts the digital histogram.
C) may result in suboptimum digital images.
D) all of the above

Correct Answer

verifed

verified

D

The area of the focal spot that is projected out of the tube toward the object being radiographed is the


A) effective focal spot.
B) line focus.
C) actual focal spot.
D) x-ray tube long axis.

Correct Answer

verifed

verified

All of the following are related except one.Select the one that is NOT RELATED.


A) a source of electrons
B) a vacuum
C) thermionic emission
D) a large potential difference

Correct Answer

verifed

verified

How many heat units are generated by an exposure of 70 kVp, 400 mA, and 0.1 second on a 3 Ï•\phi rectified unit?

Correct Answer

verifed

verified

Driving the thermionic cloud from the cathode to the anode requires


A) a grid biased anode.
B) a small voltage.
C) a large amperage.
D) a small amperage.

Correct Answer

verifed

verified

All of the following are preferred cathode filament materials EXCEPT


A) copper.
B) tungsten.
C) rhenium.
D) molybdenum.

Correct Answer

verifed

verified

How many heat units are generated by an exposure of 70 kVp, 300 mA, and 0.1 second on a 1 Ï•\phi rectified unit?

Correct Answer

verifed

verified

Showing 1 - 20 of 50